10in1 Combi Valve


Application

  • High (mains) pressure commercial ring mains.


Features & Benefits

Features and Benefits

  • Pressure limiting stop valve cold (Tee)
  • Pressure limiting stop valve hot (Elbow)
  • Tempering valve (TV20C)
  • Pressure limited cold feed
  • Free-rotating Limiting Valve body
  • Filters
  • Non-returns on both hot and cold

Specifications

Specifications


20mm Pressure limiting stop valve cold
  • Isolating valve
  • Stainless steel filter 250 micron
  • Integrated Non-return
  • DR brass body
  • Pressure setting 500 kPa
  • Max temperature: 40°C
  • Max Inlet pressure: 2000 kPa
20mm Pressure limiting stop valve hot
  • Isolating valve
  • Stainless steel filter 250 micron
  • Integrated non-return
  • DR brass body
  • Pressure setting 500 kPa
  • Max temperature: 80°C
  • Max Inlet pressure: 2000 kPa
20mm Tempering Valve (TV20C)
  • Thermostatically controlled safety valve to reduce the risk of scalding
  • Maximum static supply pressure 1400 kPa
  • Maximum dynamic supply pressure 500 kPa
  • Factory set at 53°C, can be adjusted between 35°C and 60°C
  • Connections 20mm male, ¾ “ BSP
  • Hot and cold check valves for ring main installations
 

Product Codes

10IN1     500 kPa Combi-Valve



Installation & Servicing

Installation


  • Valve must be fitted by a qualified plumber
  • Installation must comply with local authority regulations
  • Flush lines before installation
  • Valve may be fitted in any orientation
  • Do not apply heat near valve during installation - this may damage the mechanism
  TEMPERATURE ADJUSTMENT
  • Remove cap, use a screwdriver to adjust to the desired temperature. To increase, turn anti-clockwise (H).
  • To decrease, turn clockwise (C). Check outlet temperature required by local authorities with a calibrated thermometer.


Standards

Standards


Complies with NZBC Clause G12 (2014) Complies with NZS 4617: 1989